This page describes how to set up a centrally driven intercom system with PS16 and Annuncicoms.
The scenario of the Intercom System is one or more call centers and many clients in the building.
Requirements
You will need the following hardware:
- one or more PS16 stations
- one or more Annuncicoms 100 or 200
- for paging purposes (output only) Exstreamers 100/200 can be used in addition or instead of the Annuncicoms
Loading the software
To set up the intercom system you will need the ABCL package. The PS16 as well as the Annuncicom 200 should come with the ABCL preloaded.
The other devices (Annuncicom 100, Exstreamer 100/200) must be loaded with the ABCL software.
Download the latest version of ABCL from the Barix Website and upload to the devices using the standard procedure.
Preparing the installation
Audio format
By default the intercom system uses mono uLaw 24kHz audio format. As an alternative you can use uLaw 8kHz or aLaw 8 or 24kHz. The audio format is configured in every device and must be the same for the whole system. Decide which format to use upfront.
IP addresses
The Intercom System uses IP for communication. At least the master station(s) must have a fixed IP address. The clients can have dynamic addresses assigned with DHCP, however, all units must be on the same subnet because the units discover each other using broadcast.
Before setting up the system consider what network addresses to use for your units. Write down the address(es) of the master station(s).
Device IDs
For better identification within the system each client has a unique 3-digit ID. This allows to have up to 1000 clients in the system. Before setting up the system consider the numbering of the clients. Here are some hints how to assign the IDs:
- ID is the same as the room number where the client is installed
- the ID is the building floor in the first digit followed by the room number
- the ID is the same as the last part of the IP address of the device
Ring tones
Configuring the clients
- Open the WEB UI of the Annuncicom/Exstreamer device in your browser and in the Application field select Intercom Client, then press Apply.
- After the unit reboots, click on the Application button on the WEB UI.
- Assign a proper ID in the "Station ID" field.
- An optional text description (name) can be assigned to each client ("Device name"). The name will be displayed on the master whenever a call is requested. By default the name is empty.
- Up to two master stations can be configured per client. Enter their IP address. Each input button on the Annuncicom 100/200 makes a call to one master.
- If you want to use other audio format than the default select it in the Encoding field.
Configuring the PS16
Open the WEB UI of the PS16 in your browser and in the Application field select Intercom Master Station, then press Apply.