==Common Gateway Interface (CGI)==
==Common Gateway Interface (CGI)==
The current configuration can also be changed using the CGI API embedded in every Barix devices. The GET method allows to set new configuration values for every variable available on the WEB user interface of the device. The method is easy but the detailed usage may depend on the tool and version used on the PC server side. Here following is an example using ''GNU Wget ver.1.11.4'':  
The current configuration can also be changed using the CGI API embedded in every Barix devices. The GET method allows to set new configuration values for every variable available on the WEB user interface of the device. The method is easy but the detailed usage may depend on the tool and version used on the PC server side. Here following is an example using ''GNU Wget ver.1.11.4'':  
In the Streaming Client Firmware we want to set the SNMP IP address to 192.168.2.111
 
On a device (IP 192.168.2.66) running the Streaming Client Firmware we want to set the SNMP server IP address to 192.168.2.111
  wget "--post-data=B686=192&B687=168&B688=2&B689=111&"  http ://192.168.2.66/setup.cgi
  wget "--post-data=B686=192&B687=168&B688=2&B689=111&"  http ://192.168.2.66/setup.cgi
The variable's name (e.g. B686) can be found looking in html source of the device WEB UI or  in Technical Documentation of the specific Firmware.
The variable's name (e.g. B686) can be found looking in html source of the device WEB UI or  in Technical Documentation of the specific Firmware.

Revision as of 17:35, 27 March 2009

Configuration Update

The current configuration is stored in a non-volatile memory (EEPROM). The memory layout depends on the specific Firmware. If you updated the device with a new Firmware make sure to apply the “factory defaults configuration”. The current configuration can be changed via the web user interface. When hit the “Apply” button the new values are stored into the EEPROM.

Factory defaults using Serial Rescue

The EEPROM is overwritten during a Serial Rescue by the factory defaults configuration using the binary file config.bin which is located in the folder “update_rescue” of the delivered Firmware Update Kit. This file can be edited with a hex editor. Consult the “configuration memory usage” table carefully before you make any changes.

Factory defaults using Web Update

The “factory defaults configuration” (config.bin) is also contained in the application image which is loaded into the flash memory. When applying the “Web Update” make sure to apply the “factory defaults configuration” by pushing the reset button for more than 10 seconds.

Common Gateway Interface (CGI)

The current configuration can also be changed using the CGI API embedded in every Barix devices. The GET method allows to set new configuration values for every variable available on the WEB user interface of the device. The method is easy but the detailed usage may depend on the tool and version used on the PC server side. Here following is an example using GNU Wget ver.1.11.4:

On a device (IP 192.168.2.66) running the Streaming Client Firmware we want to set the SNMP server IP address to 192.168.2.111

wget "--post-data=B686=192&B687=168&B688=2&B689=111&"  http ://192.168.2.66/setup.cgi

The variable's name (e.g. B686) can be found looking in html source of the device WEB UI or in Technical Documentation of the specific Firmware.