Difference between revisions of "Automation and Control Product Matrix"
| Line 9: | Line 9: | ||
| !width="65" bgcolor="#F00" align="center" style="color:#FFF;"| R6 | !width="65" bgcolor="#F00" align="center" style="color:#FFF;"| R6 | ||
| !width="65" bgcolor="#F00" align="center" style="color:#FFF;"| X8 | !width="65" bgcolor="#F00" align="center" style="color:#FFF;"| X8 | ||
| |- | |||
| !bgcolor="#DDD"| Device Type | |||
| |bgcolor="#DDD" align="center" | Programmable Controller | |||
| |bgcolor="#DDD" align="center" | Programmable Controller | |||
| |bgcolor="#DDD" align="center" | Modbus Extension Module | |||
| |bgcolor="#DDD" align="center" | Modbus Extension Module | |||
| |bgcolor="#DDD" align="center" | Modbus Extension Module | |||
| |- | |- | ||
| ! Ethernet | ! Ethernet | ||
| Line 60: | Line 67: | ||
| |- | |- | ||
| !bgcolor="#DDD"|Wiegand IF | !bgcolor="#DDD"|Wiegand IF | ||
| ||   | |bgcolor="#DDD"| | ||
| |bgcolor="#DDD" align="center" | 2 [1] | |bgcolor="#DDD" align="center" | 2 [1] | ||
| |bgcolor="#DDD"| | |bgcolor="#DDD"| | ||
| Line 71: | Line 78: | ||
| || | || | ||
| || | || | ||
| |align="center"| 8 [2] | |align="center"| 0..8 [2] | ||
| |- | |- | ||
| !bgcolor="#DDD"| Analog Inputs | !bgcolor="#DDD"| Analog Inputs | ||
| Line 78: | Line 85: | ||
| |bgcolor="#DDD"| | |bgcolor="#DDD"| | ||
| |bgcolor="#DDD"| | |bgcolor="#DDD"| | ||
| |bgcolor="#DDD" align="center" | 0..8 [ | |bgcolor="#DDD" align="center" | 0..8 [2] | ||
| |- | |- | ||
| ! Digital Inputs | ! Digital Inputs | ||
| |align="center"| 4 dry contact  | |align="center"| 4 dry contact (fixed pull-up)   | ||
| |align="center"| 8 dry contact/0..5VDC (sel. pull-up) | |align="center"| 8 dry contact / 0..5VDC (sel. pull-up) | ||
| |align="center"| 12  | |align="center"| 12 Opto iso. 0..32VDC | ||
| || | || | ||
| |align="center"| [ | |align="center"| 0..8 [2] | ||
| |- | |- | ||
| !bgcolor="#DDD"| Digital Outputs (24VDCmax) '''   | !bgcolor="#DDD"| Digital Outputs (24VDCmax) '''   | ||
| |bgcolor="#DDD"| | |bgcolor="#DDD"| | ||
| |bgcolor="#DDD" align="center" | 4 (0.1A sink) | |bgcolor="#DDD" align="center" | 4 (0.1A sink) | ||
| |bgcolor="#DDD" align="center" | 12 (0.7A source) | |||
| |bgcolor="#DDD"| | |bgcolor="#DDD"| | ||
| |bgcolor="#DDD"| | |bgcolor="#DDD"| | ||
| |- | |- | ||
| ! Relais Out (30Vmax) '''   | ! Relais Out (30Vmax) '''   | ||
Revision as of 14:27, 9 November 2010
Automation and Control Product Matrix
Comparison of HW and SW features
| Barionet 50 | Barionet 100 | IO12 | R6 | X8 | |
|---|---|---|---|---|---|
| Device Type | Programmable Controller | Programmable Controller | Modbus Extension Module | Modbus Extension Module | Modbus Extension Module | 
| Ethernet | 10/100 auto | 10/100 auto | |||
| Modbus Type (TCP) | Slave (RTU) | Slave (RTU) | |||
| Modbus Type (RS-485) | Master | Master | Slave | Slave | Slave | 
| RS-485 Baudrate | 300..230400 | 300..19200 | 9600/19200 | 9600/19200 | 9600/19200 | 
| RS-422 (4-wire) | ✔ | ||||
| RS-232 Signals | TxD, RxD, RTS, CTS, GND | TxD, RxD, RTS, CTS, GND | |||
| RS-232 Baudrate | 300..230400 | 300..19200 | |||
| Wiegand IF | 2 [1] | ||||
| 1-Wire IF | 1 | 1 | 0..8 [2] | ||
| Analog Inputs | 4 [3] | 0..8 [2] | |||
| Digital Inputs | 4 dry contact (fixed pull-up) | 8 dry contact / 0..5VDC (sel. pull-up) | 12 Opto iso. 0..32VDC | 0..8 [2] | |
| Digital Outputs (24VDCmax) | 4 (0.1A sink) | 12 (0.7A source) | |||
| Relais Out (30Vmax) | 4 NO (30V 0.5A) | 2 NO (250V 5A) | 6 NO (250V 10A) | 
Back to Main Page