Difference between revisions of "Automation and Control Product Matrix"
Line 3: | Line 3: | ||
{| | {| | ||
|+align="bottom" style="bold" |''Comparison of HW and SW features" | |+align="bottom" style="bold" |''Comparison of HW and SW features" | ||
!width=" | !width="145" | | ||
!width="120" bgcolor="#F00" align="center" style="color:#FFF;"| Barionet 50 | !width="120" bgcolor="#F00" align="center" style="color:#FFF;"| Barionet 50 | ||
!width="120" bgcolor="#F00" align="center" style="color:#FFF;"| Barionet 100 | !width="120" bgcolor="#F00" align="center" style="color:#FFF;"| Barionet 100 | ||
Line 19: | Line 19: | ||
!bgcolor="#DDD"| Modbus Type (TCP) | !bgcolor="#DDD"| Modbus Type (TCP) | ||
|bgcolor="#DDD" align="center" | Slave (RTU) | |bgcolor="#DDD" align="center" | Slave (RTU) | ||
|bgcolor="#DDD"| Slave (RTU) | |bgcolor="#DDD" align="center" | Slave (RTU) | ||
|| | |bgcolor="#DDD"| | ||
|| | |bgcolor="#DDD"| | ||
|| | |bgcolor="#DDD"| | ||
|- | |- | ||
! Modbus Type (RS-485) | ! Modbus Type (RS-485) | ||
Line 32: | Line 32: | ||
|- | |- | ||
! RS-485 Baudrate | ! RS-485 Baudrate | ||
|align="center"| 300..230400 | |bgcolor="#DDD" align="center" | 300..230400 | ||
|align="center"| 300..19200 | |bgcolor="#DDD" align="center" | 300..19200 | ||
|align="center"| 9600/19200 | |bgcolor="#DDD" align="center" | 9600/19200 | ||
|align="center"| 9600/19200 | |bgcolor="#DDD" align="center" | 9600/19200 | ||
|align="center"| 9600/19200 | |bgcolor="#DDD" align="center" | 9600/19200 | ||
|- | |- | ||
! RS-422 (4-wire) | ! RS-422 (4-wire) |
Revision as of 14:08, 9 November 2010
Automation and Control Product Matrix
Comparison of HW and SW features
Barionet 50 | Barionet 100 | IO12 | R6 | X8 | |
---|---|---|---|---|---|
Ethernet | 10/100 auto | 10/100 auto | |||
Modbus Type (TCP) | Slave (RTU) | Slave (RTU) | |||
Modbus Type (RS-485) | Master | Master | Slave | Slave | Slave |
RS-485 Baudrate | 300..230400 | 300..19200 | 9600/19200 | 9600/19200 | 9600/19200 |
RS-422 (4-wire) | ✔ | ||||
RS-232 Signals | TxD, RxD, RTS, CTS, GND | TxD, RxD, RTS, CTS, GND | |||
RS-232 Baudrate | 300..230400 | 300..19200 | |||
Wiegand IF | 2 [1] | ||||
1-Wire IF | 1 | 1 | 8 [2] | ||
Analog In (0..5VDC) | 4 [3] | 8 [4] | |||
Digital In | 4 dry contact In (fix pull-up) | 8 dry contact/0..5VDC (sel. pull-up) | 12 Optical isolated 0..32VDC | [8] | |
Digital Out (24VDCmax) | 4 (0.1A sink) | ||||
Digital Out (32VDCmax) | 12 (0.7A source) | ||||
Relais Out (30Vmax) | 4 NO (0.5A) | ||||
Relais Out (250Vmax) | 2 NO (5A) | 6 NO (10A) |