!bgcolor="#DDDDDD"| Serial Interface | !bgcolor="#DDDDDD"| Serial Interface | ||
|bgcolor="#FFFFFFFF" align="center" | 1 (DSub-9 male) RS-232 Serial Port | |bgcolor="#FFFFFFFF" align="center" | 1 (DSub-9 male) RS-232 Serial Port | ||
|bgcolor="#FFFFFFFF" align="center" | 1 RS-232 | |bgcolor="#FFFFFFFF" align="center" | 1 RS-232 (DSub-9 male, RX/TX only)<br>1 RS-422/485 # (2/4 wire) | ||
|bgcolor="#FFFFFFFF" align="center" |1 RS-232<br>DSub-9 male, 5-wire RXD, TXD, RTS, CTS, GND<br>1 RS-485 on detachable screw terminal block as well as on 4 pin extension connectors, | |||
|bgcolor="#FFFFFFFF" align="center" | - | |||
1 RS-485 on detachable screw terminal block as well as on 4 pin extension connectors, | |||
both with serial speeds from 300 bps to 230 kbps (asynchronous) | both with serial speeds from 300 bps to 230 kbps (asynchronous) | ||
|- | |||
!bgcolor="#DDDDDD"| LED | |||
|bgcolor="#FFFFFFFF" align="center" | 11 LED status indicators | |||
|bgcolor="#FFFFFFFF" align="center" | 10 LED status indicators | |||
|bgcolor="#FFFFFFFF" align="center" | 8 LED status indicators | |||
|- | |||
!bgcolor="#DDDDDD"| '''I/O interfaces:''' | |||
|bgcolor="#DDDDDD" align="center" | | |||
|bgcolor="#DDDDDD" align="center" | | |||
|bgcolor="#DDDDDD" align="center" | | |||
|- | |||
!bgcolor="#DDDDDD"| Relay | |||
|bgcolor="#FFFFFFFF" align="center" | 2 relay outputs (max: 30VDC 5A) | |||
|bgcolor="#FFFFFFFF" align="center" | 2 relay outputs (240 VAC 5 A) | |||
|bgcolor="#FFFFFFFF" align="center" | 4 relay outputs (30 VDC, 0.5 A) | |||
|- | |||
!bgcolor="#DDDDDD"| Output | |||
|bgcolor="#FFFFFFFF" align="center" | 4 open collector (digital) outputs (4x24VDC, 0.3A) | |||
|bgcolor="#FFFFFFFF" align="center" | 4 digital outputs (open collector, 24 V 0.1 A) | |||
|bgcolor="#FFFFFFFF" align="center" | -- | |||
|- | |||
!bgcolor="#DDDDDD"| Input | |||
|bgcolor="#FFFFFFFF" align="center" | 8 contact closure Inputs (0-15VDC), of which <br>4 are 12 Bit analogue Inputs (0-15VDC) | |||
|bgcolor="#FFFFFFFF" align="center" | 4 digital inputs (0-12 V),<br> configurable pullups<br> 4 universal inputs (analogue 0-<br>5/10 V or<br> digital 0-12 V) with configurable<br> pullups | |||
|bgcolor="#FFFFFFFF" align="center" | 4 digital inputs (dry contacts) | |||
|- | |||
!bgcolor="#DDDDDD"| 1 Wire Interface | |||
|bgcolor="#FFFFFFFF" align="center" | 1-molex connector J3 | |||
(interface for external temperature sensors 18DS20 or other 1-Wire equipment) | |||
|bgcolor="#FFFFFFFF" align="center" | | |||
2 Barix extension bus connectors with Dallas 1-Wire capability | |||
|bgcolor="#FFFFFFFF" align="center" | | |||
1 Dallas 1-Wire interface | |||
|- | |||
!bgcolor="#DDDDDD"| Power Supply Voltage | |||
|bgcolor="#FFFFFFFF" align="center" | 9-30VDC, 2.5W max | |||
|bgcolor="#FFFFFFFF" align="center" | 9-30 VDC, 4W max | |||
|bgcolor="#FFFFFFFF" align="center" | 9-30 VDC, 4W max | |||
|- | |||
!bgcolor="#DDDDDD"| '''Software:''' | |||
|bgcolor="#DDDDDD" align="center" | | |||
|bgcolor="#DDDDDD" align="center" | | |||
|bgcolor="#DDDDDD" align="center" | | |||
|- | |||
!bgcolor="#DDDDDD"| Operating System | |||
|bgcolor="#FFFFFFFF" align="center" | Linux OpenWrt Caos Calmer | |||
|bgcolor="#FFFFFFFF" align="center" | Barix proprietary (BCL) | |||
|bgcolor="#FFFFFFFF" align="center" | Barix proprietary (BCL) | |||
|- | |||
!bgcolor="#DDDDDD"| Interpreter | |||
|bgcolor="#FFFFFFFF" align="center" | Python 2.7 compiler (pre-installed) | |||
|bgcolor="#FFFFFFFF" align="center" | BCL | |||
|bgcolor="#FFFFFFFF" align="center" | BCL | |||
|- | |||
!bgcolor="#DDDDDD"| Protocols | |||
|bgcolor="#FFFFFFFF" align="center" | TCP/IP, DHCP, HTTP | |||
|bgcolor="#FFFFFFFF" align="center" | TCP/IP, DHCP, HTTP, SNMP, Modbus/TCP, CGI | |||
|bgcolor="#FFFFFFFF" align="center" | TCP/IP, DHCP, HTTP, SNMP, Modbus/TCP, CGI | |||
|- | |||
!bgcolor="#DDDDDD"| Apps | |||
|bgcolor="#FFFFFFFF" align="center" | https://wiki.openwrt.org/doc/howto/start | |||
|bgcolor="#FFFFFFFF" align="center" | http://www.bcl-applications.info/ | |||
|bgcolor="#FFFFFFFF" align="center" | http://www.bcl-applications.info/ | |||
|- | |||
!bgcolor="#DDDDDD"| '''Board:''' | |||
|bgcolor="#DDDDDD" align="center" | | |||
|bgcolor="#DDDDDD" align="center" | | |||
|bgcolor="#DDDDDD" align="center" | | |||
|- | |||
!bgcolor="#DDDDDD"| | |||
|bgcolor="#FFFFFFFF" align="center" | QINO | |||
|bgcolor="#FFFFFFFF" align="center" | Lantronix Xport | |||
|bgcolor="#FFFFFFFF" align="center" | Lantronix DSTni | |||
|- | |||
!bgcolor="#DDDDDD"| '''Availability:''' | |||
|bgcolor="#DDDDDD" align="center" | | |||
|bgcolor="#DDDDDD" align="center" | | |||
|bgcolor="#DDDDDD" align="center" | | |||
|- | |||
!bgcolor="#DDDDDD"| | |||
|bgcolor="#FFFFFFFF" align="center" | Available | |||
|bgcolor="#FFFFFFFF" align="center" | Available | |||
|bgcolor="#FFFFFFFF" align="center" | Available | |||
|} | |||
More information available in our website: http://www.barix.com<br> | |||
Back to [[Main Page#Products]] |
Latest revision as of 12:45, 30 May 2017
BARIX Barionet family comparison matrix
Comparison of HW and SW features
Barionet 1000 | Barionet 100 | Barionet 50 | |
---|---|---|---|
Device Type | Single Board Computer | Programmable controller | Programmable controller |
Hardware: | |||
CPU | MediaTek MT7620A (580 MHz) | Microchip PIC 16F877A | cFeon EN29LV160B |
Memory | 64MB DRAM / 16MB Flash | 368 Bytes RAM / 14KB Flash | 16MB Flash |
Network Interfaces: | |||
Ethernet | 1 Port RJ45 Port 10/100 Mbps | 1 Port RJ45 10/100 Mbit | 1 Port RJ45 10/100 Mbit |
RF | 1 Wi-Fi 802.11 b/g/n, 2.4 Ghz | -- | -- |
USB interfaces | 2 USB host ports (2.0) | -- | -- |
Serial Interface | 1 (DSub-9 male) RS-232 Serial Port | 1 RS-232 (DSub-9 male, RX/TX only) 1 RS-422/485 # (2/4 wire) |
1 RS-232 DSub-9 male, 5-wire RXD, TXD, RTS, CTS, GND 1 RS-485 on detachable screw terminal block as well as on 4 pin extension connectors, both with serial speeds from 300 bps to 230 kbps (asynchronous) |
LED | 11 LED status indicators | 10 LED status indicators | 8 LED status indicators |
I/O interfaces: | |||
Relay | 2 relay outputs (max: 30VDC 5A) | 2 relay outputs (240 VAC 5 A) | 4 relay outputs (30 VDC, 0.5 A) |
Output | 4 open collector (digital) outputs (4x24VDC, 0.3A) | 4 digital outputs (open collector, 24 V 0.1 A) | -- |
Input | 8 contact closure Inputs (0-15VDC), of which 4 are 12 Bit analogue Inputs (0-15VDC) |
4 digital inputs (0-12 V), configurable pullups 4 universal inputs (analogue 0- 5/10 V or digital 0-12 V) with configurable pullups |
4 digital inputs (dry contacts) |
1 Wire Interface | 1-molex connector J3
(interface for external temperature sensors 18DS20 or other 1-Wire equipment) |
2 Barix extension bus connectors with Dallas 1-Wire capability |
1 Dallas 1-Wire interface |
Power Supply Voltage | 9-30VDC, 2.5W max | 9-30 VDC, 4W max | 9-30 VDC, 4W max |
Software: | |||
Operating System | Linux OpenWrt Caos Calmer | Barix proprietary (BCL) | Barix proprietary (BCL) |
Interpreter | Python 2.7 compiler (pre-installed) | BCL | BCL |
Protocols | TCP/IP, DHCP, HTTP | TCP/IP, DHCP, HTTP, SNMP, Modbus/TCP, CGI | TCP/IP, DHCP, HTTP, SNMP, Modbus/TCP, CGI |
Apps | https://wiki.openwrt.org/doc/howto/start | http://www.bcl-applications.info/ | http://www.bcl-applications.info/ |
Board: | |||
QINO | Lantronix Xport | Lantronix DSTni | |
Availability: | |||
Available | Available | Available |