Difference between revisions of "ESD protection enhancement how-to"
m (New page: This how-to will guide you step by step to mount the Barix ESD protection enhancement springs. The springs can be ordered directly with Barix using this form: "Link coming soon" == Step ...) |
|||
(16 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
[[Main_Page#Hardware_Topics|Hardware_Topics]] >> [[ESD_protection_enhancement_how-to]] | |||
== Introduction == | |||
This how-to will guide you step by step to mount the Barix ESD protection enhancement springs. | This how-to will guide you step by step to mount the Barix ESD protection enhancement springs. | ||
The springs can be | The application of the springs will enhance the ESD protection by making a better connection between the shielding of the RS-232 connector and the device enclosure (aluminum housing). Note that this does NOT alter the insulation between device shielding and the internal ground (analog / digital signal ground). | ||
The springs can be requested directly from Barix using either this [http://www.barix.com/esdsprings/index.php online form], this [mailto:esdsprings@barix.com?Subject=Request%20for%20ESD%20protection%20enhancement%20springs&body=Dear%20Barix%20Support%0D%0DThis%20is%20a%20request%20for%20participation%20in%20the%20ESD%20protection%20enhancement%20program%20by:%0D%0DCompany_name:%0DFirst_name:%0DLast_name:%0DEmail:%0DPhone_number:%0DShipping_address:%0DComment_remarks:%0D%0D(Please%20fill%20in%20the%20MAC%20address,%20the%20production%20week%20and%20year%20and%20state%20the%20symptom(s).%20Copy%20the%20four%20lines%20for%20each%20additional%20device)%0D%0DProduct:EX100%0DMAC_address:00-08-E1-xx-yy-zz%0DPW:xx/11%0DSymptom:Device_heating,%20Power_Supply_damage%0D%0D email form] or by sending an email to [mailto:esdsprings@barix.com?Subject=Request%20for%20ESD%20protection%20enhancement%20springs esdsprings@barix.com] ([[ESDsamplebodytext|Click here for a sample body text]]). | |||
To enlarge click on any of the photos. | |||
== Step 1: Preparation == | == Step 1: Preparation == | ||
Unpack the device and the springs. Place the device on the table with the rear plate facing up. | Unpack the device and the springs. Place the device on the table with the rear plate facing up. | ||
[[Image:ESDpe1.png|200px]][[Image:ESDpe2.png|200px]] | [[Image:ESDpe1.png|200px]][[Image:ESDpe2.png|200px]] | ||
== Step 2: Unscrewing the bolts == | == Step 2: Unscrewing the bolts == | ||
Use appropriate tools to unscrew the left and right Dsub bolts of the RS-232 connector. | Use appropriate tools to unscrew the left and right Dsub bolts of the RS-232 connector. | ||
Place the bolts aside for mounting in the final steps. | Place the bolts aside for mounting in the final steps. | ||
[[Image:ESDpe3.png|200px]][[Image:ESDpe4.png|200px]] | [[Image:ESDpe3.png|200px]][[Image:ESDpe4.png|200px]] | ||
== Step 3: Placing the springs == | |||
Use pliers or a tweezer to place the springs in the slot between the RS-232 connector and the enclosure. | |||
*The bent part with the screw hole must be placed facing up! | |||
*Place the spring to fit the screw hole for easy mounting of the bolts. | |||
*Production tolerances might prevent you from placing both spring which is ok as long as one spring is touching the enclosure. | |||
[[Image:ESDpe5.png|200px]][[Image:ESDpe6.png|200px]][[Image:ESDpe7.png|200px]] | |||
== Step 4: Screwing back on the bolts == | |||
Use appropriate tools to screw back on the left and right Dsub bolts of the RS-232 connector. | |||
*Place both bolts in loosely before tightening them! | |||
*Tighten both bolts to prevent accidental untightening. | |||
[[Image:ESDpe8.png|200px]][[Image:ESDpe9.png|200px]][[Image:ESDpe10.png|200px]] |
Latest revision as of 10:22, 26 August 2011
Hardware_Topics >> ESD_protection_enhancement_how-to
Introduction
This how-to will guide you step by step to mount the Barix ESD protection enhancement springs.
The application of the springs will enhance the ESD protection by making a better connection between the shielding of the RS-232 connector and the device enclosure (aluminum housing). Note that this does NOT alter the insulation between device shielding and the internal ground (analog / digital signal ground).
The springs can be requested directly from Barix using either this online form, this email form or by sending an email to esdsprings@barix.com (Click here for a sample body text).
To enlarge click on any of the photos.
Step 1: Preparation
Unpack the device and the springs. Place the device on the table with the rear plate facing up.
Step 2: Unscrewing the bolts
Use appropriate tools to unscrew the left and right Dsub bolts of the RS-232 connector. Place the bolts aside for mounting in the final steps.
Step 3: Placing the springs
Use pliers or a tweezer to place the springs in the slot between the RS-232 connector and the enclosure.
- The bent part with the screw hole must be placed facing up!
- Place the spring to fit the screw hole for easy mounting of the bolts.
- Production tolerances might prevent you from placing both spring which is ok as long as one spring is touching the enclosure.
Step 4: Screwing back on the bolts
Use appropriate tools to screw back on the left and right Dsub bolts of the RS-232 connector.
- Place both bolts in loosely before tightening them!
- Tighten both bolts to prevent accidental untightening.