-- Barix MIB Registration Authority -- This is the authority for defining MIB items under barix.products.abcl { enterprises 17491 1 5 } -- If new branches are needed then this file MUST be updated -- Version: 1.0 -- Date: 12 June, 2008 -- Copyright (c) 2008 Barix AG -- Changes: -- 20080612 Petr Kulhavy created BARIX-ABCL-TRAPS-MIB DEFINITIONS ::= BEGIN IMPORTS sysUpTime FROM RFC1213-MIB abcl, gptIndex, gptValue FROM BARIX-MIB TRAP-TYPE FROM RFC-1215; -- General Traps -- Traps in the range 0 to 999 are allocated for general purpose use. keepalive TRAP-TYPE ENTERPRISE abcl VARIABLES { sysUpTime } DESCRIPTION "A keepalive trap signalises that the system is still alive." ::=1 -- OEM specific traps -- Traps starting from number 1000 are reserved for OEM specific projects. -- Audio Bridge for public transport -- Allocated range 1000 to 1099 amplifier1AlarmCleared TRAP-TYPE ENTERPRISE abcl VARIABLES { sysUptime, gptIndex, gptValue, gptIndex, gptValue, gptIndex, gptValue, gptIndex, gptValue } DESCRIPTION "An amplifier1AlarmCleared trap signalises end of error condition 'Amplifier 1 Alarm' and is sent when the amplifier error of the first amplifier is resolved (the respective digital input is inactive). The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description." ::=1000 amplifier1Alarm TRAP-TYPE ENTERPRISE abcl VARIABLES { sysUptime, gptIndex, gptValue, gptIndex, gptValue, gptIndex, gptValue, gptIndex, gptValue } DESCRIPTION "An amplifier1Alarm trap signalises an alarm condition on the first amplifier. The trap is triggered by activity on the respective digital input. The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description." ::=1001 amplifier2AlarmCleared TRAP-TYPE ENTERPRISE abcl VARIABLES { sysUptime, gptIndex, gptValue, gptIndex, gptValue, gptIndex, gptValue, gptIndex, gptValue } DESCRIPTION "An amplifier2AlarmCleared trap signalises end of error condition 'Amplifier 2 Alarm' and is sent when the amplifier error of the second amplifier is resolved (the respective digital input is inactive). The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description." ::=1002 amplifier2Alarm TRAP-TYPE ENTERPRISE abcl VARIABLES { sysUptime, gptIndex, gptValue, gptIndex, gptValue, gptIndex, gptValue, gptIndex, gptValue } DESCRIPTION "An amplifier2Alarm trap signalises an alarm condition on the second amplifier. The trap is triggered by activity on the respective digital input. The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description." ::=1003 partnerMissingCleared TRAP-TYPE ENTERPRISE abcl VARIABLES { sysUptime, gptIndex, gptValue, gptIndex, gptValue, gptIndex, gptValue, gptIndex, gptValue } DESCRIPTION "A partnerMissingCleared trap signalises end of error condition 'Partner Missing' and is sent when the respective partner comes on-line. The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description." ::=1004 partnerMissing TRAP-TYPE ENTERPRISE abcl VARIABLES { sysUptime, gptIndex, gptValue, gptIndex, gptValue, gptIndex, gptValue, gptIndex, gptValue } DESCRIPTION "A partnerMissing trap signalises a loss of the communication partner. The trap is sent only once when the partner is not responding for more than 60 seconds. The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description." ::=1005 noAudioCleared TRAP-TYPE ENTERPRISE abcl VARIABLES { sysUptime, gptIndex, gptValue, gptIndex, gptValue, gptIndex, gptValue, gptIndex, gptValue } DESCRIPTION "A noAudioCleared trap signalises end of error condition 'No Audio' and is sent when the output audio level raises above the minimum level. The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description." ::=1006 noAudio TRAP-TYPE ENTERPRISE abcl VARIABLES { sysUptime, gptIndex, gptValue, gptIndex, gptValue, gptIndex, gptValue, gptIndex, gptValue } DESCRIPTION "A noAudio trap is sent if the audio output peak level is too low for a certain (configured) period of time while a valid audio stream is being received. This condition signalises a potential error in analog circuitry. The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description." ::=1007 END